F500 for cooling down the lamp. CF for control the temperature of sample in the reactor
Model: 7864
Order NO.: 7864
892
Specific parameters will be adjusted according to product upgrades, without notice.
● F500 for cooling down the lamp
● CF for control the temperature of sample in the reactor
250mL System
C7865-410
No. |
Order No. |
Product Description |
Qty |
1 |
JRS-7865-06 |
Reactor Body, 250mL, #50 Thread,with jacket and bottom outlet |
1 |
2 |
JRS-7874-38 |
Quartz Immersion Well |
1 |
3 |
JRS-7841-09 |
Sparger Tube |
1 |
4 |
JRS-13654-14 |
Stir bar, PTFE |
1 |
5 |
JRS-5029-10 |
#7 Nylon Bushing |
1 |
6 |
JRS-7506-14 |
#50 Ace-Thred Nylon Bushing |
1 |
7 |
JRS-12687-12 |
FEP Tubing |
1 |
8 |
JRS-7837-02 |
Stand Insert, PTFE, 250mL |
1 |
9 |
JRS-7825-34 |
Immersion Lamp, 450W |
1 |
10 |
JRS-7830-61 |
Power Supply, 230V, 50Hz |
1 |
11 |
JRS-12168-230 |
Water flow monitor. |
1 |
12 |
JRS-12168-03 |
Flow sensor. Flow rate: 2 to 30 L/min |
1 |
13 |
JRS-12168-10 |
Water shut off valve. Turns off water flow during an alarm. |
1 |
14 |
WFM-AA |
Audible Alarm. Alarm (70 dB) sounds during under flow condition. |
1 |
15 |
WFM-OC |
Digital Alarm Outlet. High current (170 ma) open collector output. |
1 |
16 |
JRS-9860-34 |
Safety reaction cabinet for the safe operation of photochemical reaction equipment. |
1 |
17 |
JRS-12160-35 |
Water filter |
1 |
500mL System
C7865-430
No. |
Order No. |
Product Description |
Qty |
1 |
JRS-7865-08 |
Reactor Body, 500mL, #50 Thread, with jacket and bottom outlet |
1 |
2 |
JRS-7874-38 |
Quartz Immersion Well |
1 |
3 |
JRS-7841-09 |
Sparger Tube |
1 |
4 |
JRS-13654-14 |
Stir bar, PTFE |
1 |
5 |
JRS-5029-10 |
#7 Nylon Bushing |
1 |
6 |
JRS-7506-14 |
#50 Ace-Thred Nylon Bushing |
1 |
7 |
JRS-12687-12 |
FEP Tubing |
1 |
8 |
JRS-7837-05 |
Stand Insert, PTFE, 500mL |
1 |
9 |
JRS-7825-34 |
Immersion Lamp, 450W |
1 |
10 |
JRS-7830-61 |
Power Supply, 230V, 50Hz |
1 |
11 |
JRS-12168-230 |
Water flow monitor. |
1 |
12 |
JRS-12168-03 |
Flow sensor. Flow rate: 2 to 30 L/min |
1 |
13 |
JRS-12168-10 |
Water shut off valve. Turns off water flow during an alarm. |
1 |
14 |
WFM-AA |
Audible Alarm. Alarm (70 dB) sounds during under flow condition. |
1 |
15 |
WFM-OC |
Digital Alarm Outlet. High current (170 ma) open collector output. |
1 |
16 |
JRS-9860-34 |
Safety reaction cabinet for the safe operation of photochemical reaction equipment. |
1 |
17 |
JRS-12160-35 |
Water filter |
1 |
1000mL System
C7865-450
No. |
Order No. |
Product Description |
Qty |
1 |
JRS-7865-10 |
Reactor Body, 1000mL, #50 Thread, with jacket and bottom outlet |
1 |
2 |
JRS-7874-38 |
Quartz Immersion Well |
1 |
3 |
JRS-7841-09 |
Sparger Tube |
1 |
4 |
JRS-13654-14 |
Stir bar, PTFE |
1 |
5 |
JRS-5029-10 |
#7 Nylon Bushing |
1 |
6 |
JRS-7506-14 |
#50 Ace-Thred Nylon Bushing |
1 |
7 |
JRS-12687-12 |
FEP Tubing |
1 |
8 |
JRS-7837-10 |
Stand Insert, PTFE, 1000mL |
1 |
9 |
JRS-7825-34 |
Immersion Lamp, 450W |
1 |
10 |
JRS-7830-61 |
Power Supply, 230V, 50Hz |
1 |
11 |
JRS-12168-230 |
Water flow monitor. |
1 |
12 |
JRS-12168-03 |
Flow sensor. Flow rate: 2 to 30 L/min |
1 |
13 |
JRS-12168-10 |
Water shut off valve. Turns off water flow during an alarm. |
1 |
14 |
WFM-AA |
Audible Alarm. Alarm (70 dB) sounds during under flow condition. |
1 |
15 |
WFM-OC |
Digital Alarm Outlet. High current (170 ma) open collector output. |
1 |
16 |
JRS-9860-34 |
Safety reaction cabinet for the safe operation of photochemical reaction equipment. |
1 |
17 |
JRS-12160-35 |
Water filter |
1 |