Flow:1.8~15 L/min, Pressure in 4.5-10 bar
Model: RACK ZERO AIR GC 1800
Order NO.:
1525
Specific parameters will be adjusted according to product upgrades, without notice.
The Chemtron GC Zero Air Generator 19" Rack is designed to supply ultrapure hydrocarbon-free zero air for GC-FID applications. Catalytic oxidation technology eliminates hydrocarbons to <0.1ppm, resulting in a flat, stable baseline, increased sensitivity, and repeatable analysis.
GC Zero Air features:
* Flow rate from 1.8 to 15 l/min
* Pressure up to 6.5 bar (95 psig)
* Zero air purity <0.1ppm HC,
* Minimal maintenance
* 2 year standard warranty
OPERATING PRINCIPLE
The 19" Zero Air Generator uses three steps to transform ambient air into analytical grade air.
STEP 1: PRE-FILTRATION
An external oil-free compressor delivers air through a high efficiency filter that traps any particles that may damage the system. The filter, which has an automatic purge system, traps oil, water, and any particles larger than 5 microns in size.
STEP 2: HC AND CO TRAPPING
The air leaving the filter enters a high temperature platinum catalyzer, which eliminates hydrocarbon molecules down to < 0.1 ppm through oxidation .
STEP 3: FINAL FILTRATION
A final pass through a high-efficiency filter prevents any kind of particles from entering the instrument.
BENEFITS
BETTER DETECTOR PERFORMANCE
The reduction of carbon monoxide and hydrocarbons (including methane) to < 0.1 ppm decreases the background noise level and gives the baseline much better stability, increasing detector sensitivity considerably and ensuring precise analytical results.
EASY INSTALLATION
Just connect a suitable oil-free compressor (optional). To save bench space, the unit can be easily wall-mounted.
LAB SAFETY
No more bottles in the lab and expensive pipelines for air distribution.
SAVE MONEY
All that the unit requires is a connection to a suitable oil-free compressor and the mains. Typically the investment is recovered in less than a year.
IMPROVED LAB EFFICIENCY
Round the clock continuous operation maximizes lab productivity, eliminating dead time for gas bottle changeover and avoiding the need for tedious instrument recalibrations.
Models |
RACK ZERO AIR GC 1800 |
RACK ZERO AIR GC 5000 |
RACK ZERO AIR GC 10000 |
RACK ZERO AIR GC 15000 |
Flow ( L/min ) |
1.8 |
5.0 |
10.0 |
15.0 |
HC & CO out |
< 0.1 |
|||
Max CO in |
50 ppm |
|||
Max HC in |
100 ppm |
|||
Max temp. in |
40 ℃ |
|||
Pressure in |
4.5-10 bar |
|||
Pressure drop |
<1 bar |
|||
Stability ( min ) |
45 |
|||
In / out connections |
1/4-1/8 ( NPT ) |
|||
Power |
110-120V 60Hz / 220-240V 50Hz |
|||
Dimensions ( mm ) |
19" standard rack |
|||
Working temp |
Amb.+15℃ |
|||
Certification |
CE, CSA, FCC |